Sunday, December 4, 2016

Shakedown Testing and Design Reiterations

Fig. 1: Current assembly of single band
    This week team EXIT established more solid ground after continuing the shakedown and reiteration process. Since last week, more parts have been fine tuned and tested as we prepare for our final presentations. Adam successfully mounted the motor onto the spindle which was secured to the webbing. A quick test was performed to see whether the  3D spindle could withstand the forces acting on it once the motor began to wind the webbing. As expected, the plastic spindle broke after only a small amount of force was applied. For prototyping purposes, 3D printing works great, however, for a future product the spindle will need to be made from a stronger material and tested again.
    Also, this week team EXIT tested the coefficient's of friction between the webbing and the padding as well as the padding and human tissue. The goal is for our webbing to slide through the padding without causing the position of the padding to be compromised with respect to the mother's abdomen. We determined that this meant there would need to be a greater coefficient between the skin and the padding rather than the webbing and the padding. We used a 500N force tester to measure the amount of force required to pull the materials across various surfaces. The device used as well as the results can be seen below in Figures 2 and 3.
Fig 2: Team EXIT conducting friction tests
Fig 3: Raw results of friction tests
    Finally, team EXIT is pleased to say that our group was showcased in this month's edition of The Banner, our school's newspaper. The article was published this past Friday, December 2nd. The article was made available online through the newspaper's website and can be viewed here.

Sunday, November 27, 2016

Shakedown Testing and Building a Prototype

      Hello. This week we did the shakedown testing on the critical modules. Wyatt has been working on the magnetic connections. After the parts he designed were printed, we tested them out. The magnets are supposed to turn to connect and then turn the other way to disconnect (They are special magnets with both positive and negative parts on both sides).We found out that they do not turn as we expected them to, so they needed redesigning. The redesigned connection works much better.
The Connection: The top is he old iteration and the bottom is the most recent

    
       We also received some parts that were previously ordered. One of which was the seat belt webbing that we plan on using. We did a tensile test on this webbing to see if it could withhold the force that was necessary for a long period of time without breaking (Special thanks to Isaac Need for his help). It did not break until subjected to hundreds of Newton's of force more than we plan on subjecting it in the real device. Moreover, when it did break it did not hurt or even startle anybody. It broke slowly and with no sharp edges. This is good news, we will continue using this webbing as planned.

  
Our Tensile test of the seat belt webbing

       We also decided to buy padding to prevent friction of the strap on the mother's belly. It was received this week and works as expected.

The padding that we will use on the woman's belly
       We designed a housing that rests on the mother and connects the motor to the Back Support. A sliding mechanism was devised to connect them. We were able to 3D print the motor housing, but the back support did not finish printing. We thought at first that it needed to print out in three parts, but before the last part could be printed I was informed that if the back support was less than an inch shorter, that it could be printed in one piece. (It is not necessary to be long enough for this prototype.) This would greatly improve strength, so hopefully this new part could be printed out soon. The foam that the mother sits on has been received, as well as the motor. The goal of building a working prototype is well within sight, although not achieved quite yet.

Sunday, November 13, 2016

Preparation Week

    This week, team EXIT member, Adam Goodwin, finalized the calculations needed to determine specific parameters to guide our group in finding a cheap motor that would suit our needs. From the calculations it was determined that the motor should be able to apply a minimum of 12 in*lbs of torque. Using a motor that meets this parameter will hopefully be able to apply a necessary force in the belt webbing of approximately 25 lbs. The goal is to transfer this force equally around the abdomen to assist the mother during her contractions. 
Figure 1: Calculation Results
Regarding motor selection, Electrical Construction and Maintenance (ECM) shared helpful tips. One of the most relevant was tip 7, that the motor should normally operate at 75 to 95% of the mx torque. Also, most motors have a safety factor of around 1.15 for power rating, so for momentary application, it could likely deliver more than its specified horse power. However, given pro tips from senior Electrical and Computer Engineering major, Cameron Schaefer, we will try to keep our max torque used less than the specified max torque to avoid breaking our motor.
    Using this information, team EXIT collaborated together to create a list of possible motors from various suppliers that would meet the above specifications. From this list we were able to confidently choose a motor to use on our device. The selected motor is from a company called Pololu which specializes in the distribution of various electronic parts and equipment including motors. Along with the motor, our group decided that it would be best to power the motor with a rechargeable battery. Below is a list of the parts that we ordered this week. 
Figure 2: Motor Selection Matrix
    Aside from the motor being ordered along with its accompanying parts; we received the parts that were ordered last week which included the poly magnet, the belt webbing, and the padded belt slider. Since we had the magnets to work with, Wyatt Dean was able to 3D print the connector fittings and perform initial fitting tests, as well as, design iterations to fix some tolerance issues. A preliminary shakedown was also performed on the belt and slider to see if there was a sufficiently low enough coefficient of friction to allow the parts to slide freely. This coming week, we plan to use a tensometer to test the coefficients of friction. Monday, the plan is to perform tensile tests on small segments of our belt webbing to see how much force it can withstand in tension.
    Moving forward, if this week's tests prove to be successful, we hope to have one belt and motor functioning by the end of the week per our client's request. 

Monday, November 7, 2016

Redesign, Research, and Calculations

Redesign, Research, and Calculations

This week members focused on their respective modules, attempting to nail down which materials needed to be ordered, and what this iteration of the design should look like.

Joel spent time working on the slider on the mother's abdomen. He was approaching finishing the CAD drawings for this design, when our tech adviser, Dr. Gordon, suggested we use a seat belt shoulder/waist cushion. We decided that we would order one, since it is fairly cheap, perform some friction testing, and see if we the results were adequate.

Ruthie spent time doing calculations to determine what the thickness requirements might be for the back support given a specific material.

Wyatt has been finding a large body of research on Polymagnets and their properties. The magnet we wish to use is neodymium Iron Boron. Below is an example graph of shear to lateral displacement.



Adam has redone his calculations for the motor requirements. This was prompted by feedback from the rest of EXIT and the tech adviser during the Monday design meeting that the values seemed too high. After examination, there was a conceptual flaw in the previous thinking. More thought led to the current answer, with a motor of target torque of 5-15 in*lbs. Currently, Adam is suggesting a round faced DC motor from McMaster Carr, many of which meet the specifications produced by his calculations. Below are the conceptual drawings which led to his conclusions this week.  
Above is the integration of force on the abdomen based on Intrauterine Pressure.

Above is the free body diagram which leads us to the tension in the band, which will lead us directly to the required torque from the motor. 


Sunday, October 30, 2016

Design Refinement

This week was about refining our design and solidifying details. After talking to our client, we now have our tentative budget with which we will bring our ideas to life. We also began communication with the nursing program at CBU, both for their medical knowledge and to because of Victoria; the life-sized dummy that can go into labor. She is very helpful for helping us understand the process in which the baby must go through before he can be born. We were hoping to test our final device in her, but unfortunately the womb is not anatomically correct. Special thanks to the nursing program though, for their generousness in allowing us to see Victoria and for their time.

This is Victoria with the belly removed so that we can see the inside

       We planned how everything was going to work together by flow charts and CAD drawings. This helped us to think about details that we may not have thought through and make sure that everything fits together to work as we envisioned. After choosing which foam we were going to purchase, we then were able to incorporate that into our design. We also have the rollers that will be the interface between the woman and our device, as they will sit on her belly even though the bands will slide toward the motors.
This is our current assembly showing all of our parts and how they will fit together.  
This is how the nurse will attach our device. The red and blue parts are inseparable magnets until rotated, then they repel.

       We did research to learn more about the properties of the uterus so we can estimate how much force we need to put on the woman's abdomen, and therefore how much torque our motor needs to be able to put out. This, in addition we researched what motors are out there. We have found one motor that we tentatively decided to use, but further research is needed to make a final decision. We made many assumptions to get our necessary torque.

         
We did many calculations to find out how much torque we are going to need     

This is the final results of our calculations; the necessary Torque we will need

       While we are making progress, we are by no means done designing our device. We will continue to improve our device to make it the best we can.

Monday, October 24, 2016

Week 6 Update

This week we had the opportunity to present our progress thus far to the client and the rest of our peers. Quite exciting as some neutral perspectives saw our work and were able to provide valuable feedback to refine and direct our thoughts and design process. We were also able to answer some of the client's questions and clarify any presented ideas.

Title slide of our midterm design presentation.

A large amount of our time this week was spent writing an ethics paper regarding an engineering failure in our particular field. This was an excellent opportunity to research and discuss why ethics is so important as an engineer.

Brief screenshot of the referenced code of ethics on nspe.org.

Being resourceful engineers, we utilized the vast wealth of knowledge around us and coordinated a meeting with Dr. Terri Thompson, a professor of obstetrics and gynecology within the nursing program here at California Baptist University. She was a valuable resource in helping to guide our decision process based on her experience and knowledge. A short-write up was then created by each of the attending members since the interview was not recorded so they may collect their thoughts and reference later.

Great news! We were shown a contraction sensor and can now research this particular product to discover how it works and reconfigure it for our purposes, without violating any regulations set forth by the USPTO that is. This information is vital to the development of an additional module in our design.

 Front and back of the contraction sensor shown to us.

Sunday, October 16, 2016

Module Design

Hello Guys. We had already decided what are modules were, so this week we brainstormed ways to do each module. We then used a matrix to help us decide which one of our ideas (or a mixture of two) to go with. The matrix helped us to see which ideas did not do well in our pre-selected criterion. The first module that we did was Muscle; this is exactly how we are going to apply a force on the mothers' abdomen. Below are some of our ideas for this module:

This uses a fluid to push on the mother
Worm Screw; Tightens the band by turning the gear box
The Hugger; Turns to push on mother
The idea that we ended up using involved having a band (or multiple bands so that we could create a flow of force similar to that of the uterus) that a rotating motor would pull in to reduce the circumference of the mother's abdomen. We decided to put a hard material under the woman to support her back, otherwise we would be applying too much force on the mother's back. We chose this because it is simple enough to be easily manufactured and we could add more components to account for any problems we could foresee. It also has unlimited and precise circumference depressive capability as well as force capability.

This is the matrix we used to help decide which muscle idea to use. The green idea is the one we chose.
This is how this design was before our group redesigned it
20161015_160549.jpg20161015_160529.jpg
                              These pictures demonstrate how the design changed as the group discussed this idea

We also brainstormed ideas for  closing the device, as well as used a matrix for deciding on that as well. Our chosen method used a magnet that would repel in one orientation and attract when rotated to another orientation. A nurse would just turn it to connect both sides of the device. 


Some of our Connection Ideas


This the matrix for our Connector module. The Yellow are good ideas but the green is the idea that we chose.
We also put together a portfolio of all of our work so far and a presentation to explain it to our client.

Joel Practicing the Presentation




Sunday, October 9, 2016

Week 4 Update

Week 4 Update:


Possible Routes to Take at the Beginning of Week 4
     Tensions rose this week as the deadline approached for EXIT to finalize their decision on whether or not to move forward with our design results obtained from the previous week's decision matrix. The week started with split opinions and left us pondering whether the smart pressure band was actually a smart idea.  There was debate as to what negative effects could arise from applying a pressure to the abdomen, as well as, whether or not a pressure being applied to the abdomen would actually have any positive effect.
     Going into the week with doubts about our concept meant the team was unable to move forward with the module design until all questions were answered and each member had the chance to argue their views on the pressure band concept.  This meant setting aside additional, individual time to do more research on the application of pressures to the abdomen region and whether or not this was going to be more harmful rather than helpful.
     After a day of research, Ruthie ran across the "fundal pressure method" which is essentially the manual application of an external pressure similar to the pressure band we are wanting to develop. This boosted the groups morale and increased EXIT's confidence level to continue with this idea. However, the team still felt uneasy about the idea, so it was decided to do more research to try and  increase the confidence level in order to answer any remaining questions the team might have.  We met again as a group on Thursday, October 6th, to debrief after having done more research.  At this meeting the group finally to a unanimous decision to move forward with the pressure band idea and put a rush on the module designs in order to meet our objective deadline.
     Once the team was confident with our decision, we jumped straight into creating modules and splitting up the work among  the team members. The three main modules ("muscle", housing and ergonomics, and how to secure the device) were assigned to all members. Then the more specific modules were divided according to each member's preferences or strengths in the subject area. Joel was given the "cooling" module, Ruthie was given "sanitation", Wyatt was given "sensors", and Adam was given "controls". Below are some of the preliminary modules thought up by our group.
Preliminary Module Designs
Module Division of Labor

Sunday, October 2, 2016

Week 3: Concept Generation and Selection

Week 3: Concept Generation and Selection

EXIT has been hard at work this week! Early on in the week, we managed to select three strategies to develop concepts for: providing information for the doctor, modifying existing devices, and modifying womb pressures. That process consisted of a table where we weighed the pros and cons of each strategy as best as we could at this stage.

Strategy selection table.

Brainstorming concepts for each strategy took about an hour per session, an we developed 73, 65, and 37 concepts (with even more overlapping ideas), respectively. We were all surprised by the difficulty we found in ideation regarding womb pressures- we had been quite excited for that strategy and were a little disappointed at our result. Moving forward, we decided that it would be best for our group to skip the step of picking a strategy from our initially defined design process. Instead, we identified promising and feasible concepts from within all the strategies and moved to either reject or accept them for the next narrowing step.

Preliminary concept filtering.

Now we had narrowed down our two concepts after this, realizing they were essentially the same. The final group meeting was extensive, attempting to select a final concept. We used a design selection matrix developed by the KAIM company in the Spring 2016 Junior Design course at California Baptist University (with their express permission). The table (shown below) is an attempt to quantify engineers' intuition about their designs in the absence of data (given its employment in preliminary phases). We finished populating the sheet and will analyze it next week. 

Quantification of intuition about concepts.

Ruthie also managed to contact the head of OBGYN at a hospital in Jordan, which provided us with valuable information. Special thanks to Dr. Kamil Fram for his contribution to our knowledge base.


Joel's preferred sticky note method of brainstorming. 

The "mind map" method. 

A nice little logo Wyatt drew for us, illustrating the double meaning in our name.

Sunday, September 25, 2016

Brainstorm Crazy

      This week team EXIT put our minds together to do what one mind could not. We thought of new questions that we need to answer in our research. We also thought of questions that we would ask a professional in an informational interview. (We attempted to get an interview with a medical professional but have not found someone willing to talk to us yet.) We also thought of strategies that we could use to solve our problem. Here are some notable strategies that we thought of:
  • Pull the baby out
  • Rotation
  • Placebo device
  • Negative pressure
  • Push the baby out from inside
  • Limit the force or motion of a preexisting device
  • Magnets
  • External pressure on the mothers abdomen
  • Vibration
  • Strengthen/cover vaginal opening
  • Pump Fluid into the cavity
Wyatt Discussing an Idea
We did 5 brainstorming sessions this week.
Group Researching with Tasks behind us

Sunday, September 18, 2016

Week 1 Update

Team EXIT has been assigned to make a device to aid the birthing process without harming the mother or baby. We started by conducting an interview with the client to determine specifications and other additional expectations for the project. After significant research by each team member, we were able to produce a problem definition and a list of functional requirements for the device.

Problem Definition: Current delivery assist devices, though they reduce the required frequency of Cesarean section, can cause significant harm to both the mother and infant.


Functional Requirements:
  1. Decrease risk of operator error through ease of use
  2. Minimize maternal and infant injuries occurring during vaginal birth
  3. Reduce frequency of C-sections when compared to unassisted vaginal birth
  4. Comparable cost to current methods

We researched the literature for current assisted delivery devices and the reason why people would need assisted delivery.




Joel and Adam deliberating about functional requirements of the device.