Monday, February 27, 2017

Snap! ...the sound of our almost functioning device...

This week, the team had several tasks on their mind: troubleshoot the circuit (which last week had been soldered in the device), fix broken spindles, get the entire system working, and prepare for the midterm design review.

Early in the week, Wyatt and Adam localized the issue of the circuit malfunction to misunderstanding the pins of a mechanical switch used three times in the device. After re-soldering the connections to the pins, the circuit read the correct output signals, measured on an oscilloscope. A formal circuit diagram was drawn up. Now the only thing left to do with the electronics is to tap leads from the electronics box to connect to the EMG electrodes on the mother’s belly. These will be the one disposable part of the design.

Figure1. Soldered electronics box.
Figure2. Formal circuit diagram of T.A.C.O. electronics drawn in Multisim.
The next line of business was to fix the axle, which had broken in preliminary testing. It was thought that this occurred for two reasons: the part which had broken had been printed at 70% fill, not 100%, and the timing belt pulley had not been concentric around the axle of the motor, causing periodic slipping and unexpected stresses. We ensured that all the parts experiencing high stress were at 100% fill by replacing them with newly printed parts. Then to ensure that the timing belt pulley would be concentric around the motor axle, we used two set screws, rather than just one.  Using a power supply, the new system seemed to be working smoothly. 

Figure3. Motor with new spindles functioning off the power supply without tension.
Elated, we connected the entire system, and turned on the device. With care, we began to turn the manual potentiometer for each motor and were dismayed at the sound of snapping PLA! The timing belt was also still slipping periodically. Some analysis shows this could have been predicted. The issues were now isolated to the following: the set screws were too long, and stuck out, causing the walls of the housing to obstruct their path as they spun with the timing belt pulley; the timing belt pulley was still not concentric; and the size of the PLA spindle end was unable to handle the stresses developed when the motor was running with resistance. The system has been redesigned to include a single metal axle for the spindle, which will extend from the band, through the timing belt, into a bearing that will be connected to a mechanical support for the timing belt system. The redesign will be drawn up in SolidWorks next week.

In addition to all this, the converter had a failed print. This showed us the cross section of the part, revealing unexpected geometry. Joel worked with CBU’s resident 3D printing expert to redesign the converter to account for this artifact of the previous design. Ruthie contacted Sierra-Medical about obtaining a cow uterus for testing, and logistics and detailed plans for this process are still being worked out. Wyatt redesigned the electronics box to better organize the electronics. 

Preparation for the midterm design presentation was primarily remote, because the team did not have coinciding schedule’s this week. The presentation is  taking place this afternoon, Monday, February 27th, at Bourns Laboratory at 2:45 p.m.

And last, but certainly not least, the team decided on a name for the device: The Assisted Childbirth Orthotic, or T.A.C.O. 

Monday, February 20, 2017

Summer Biomechanics, Bioengineering and Biotransport Conference


      This week was the deadline to submit an abstract to the Summer Biomechanics, Bioengineering and Biotransport Conference. Therefore, we wrote about the reason why we made the device the way it is and the reason behind it. We briefly explained the design and included our budget. It is yet to be seen if we will be accepted to the conference.

The first page of our abstract

      We had a brainstorming session about how we are going to test our device. So far, we thought that we might simulate the human body with Ballistics gel covered in pig skin. We may also get a Cow uterus (or whatever species is cheapest) with something to simulate the surrounding tissue. We would like to electronically simulate the uterus and vaginal area going through a birth with our device as well if that is possible. Below is a list of some of our ideas in order of what will give us the most information. We plan to do many of the tertiary level tests even though it doesn't prove our device's ability to get the baby out because they still give us important information


  1. Primary
    1. Ballistics gel
      1. Pig skin
      2. Knox gelatin mix
    2. Grant Imahara
    3. Cow
      1. Uterus
      2. Vaginal wall
      3. Supporting ligaments
      4. Pig skin
      5. Pelvic structure
    4. Talk to Gordon about Abacus
  2. Secondary
    1. Band contractile ability
      1. Force transducers on sliders
    2. Pressure sensors on back (low priority)
      1. Box
  3. Tertiary
    1. IR Camera
      1. Hot spots
      2. Full charge/discharge
      3. Cycles/frequency
    2. Ability of woman to move
    3. Test electronics
      1. Emergency take off
      2. Kill switches
      3. Reverse functionality

      We improved our code by adding more situations. For example, we added in a cyclic setting that would run the motor on and off with no input. This would only be used for demonstration or testing purposes. We also added safety measures like what would happen if the sensors are not attached.
Our motor driver and Arduino connections

      The motor housing was finished. Some parts did not fit at first because of tolerancing problems and improper placement of screws, but we fixed it with power tools. The motors are functional.




Add caption


We 3D printed a part to hold the connection to the back. The connection will loop through this part. This has a 180 degree hinge to allow for flexibility and comfort for the woman.


Below is a picture of the current prototype (90% completed).

T.A.C.O. (The Assisted Childbirth Orthotic) first prototype.


Monday, February 13, 2017

Building a Prototype



      We have been very busy making each of the components of the prototype. Wyatt has been trying to get the parts of the connection to fit after printing high-precision parts. He was able to reprint it and get the connection fully functional! The two halves each attach very well to the seat belt. When you put them together, the magnets hold them together with a lot of force, but when you turn the dial then they repel each other to disconnect easily.



Demonstration of connection attachment and release along with a short test of the holding force of the assembly.


       I tested out the sensor on Wyatt's arm. I was able to obtain an output that corresponds to the level of contraction his muscles were under. I found that when his arm is at rest we receive an output in the 70's and when he contracts his muscles then we receive an output in the order of the hundreds. We were able to integrate the sensor with the motor.

Ruthie and Wyatt test out the sensor

       Meanwhile, we finished designing the motor housing. This housing has many slots to place the seat belt in to fit different sizes of  women. The parts are currently being printed. We should be done assembling them in the next couple of days.

The motor housing in solidworks
The motor housing with the cover removed to see inside



      We finished redesigning and building the back support. We went into the shop so that we could cut, bend, and fillet the 16 gauge aluminum that we ordered. We plan on screwing it into the motor housing that will be on the left side of it. We will also screw it into a 3D printed part that has holes for the connection to fit through. We thought of putting those hole in the metal, but an FEA showed us that it might break due to very small strips that would have to hold all of the force from the motor. If we 3D print it, we can make it as thick as we want for stability. That part was designed and will be printed soon.

We made the metal back brace in the machine shop.



The metal part of the back support. The left side is where the motor housing will attach.
       We previously did research on the shape of the woman's back, so after the metal part was done we cut and placed the foam in a position that would be comfortable to the woman. This foam compresses significantly, so we added many layers. We are looking into a spray glue that should hold them in place without corroding the foam or being uncomfortable.

       We are almost done with the prototype! We just need to put everything together and add any final details. I am really excited to see the final product!

The Back support with foam

Sunday, February 5, 2017

Busy Builders

Team EXIT has been busy redesigning and building the first prototype. Wyatt tested the functionality of various revisions of the connections to determine the most optimal tooth arrangement. Unfortunately, the force transducer was broken causing him to use two other force transducers of smaller magnitudes. This still allowed a relatively good estimate of which fixtures would withhold our required strength when pulled from the same point. The results were largely dependent on the quality and precision of the print. 

 
The connection is clamped while the force sensors are pulled while attached to the seat belt

The FEA analysis
Meanwhile, the back has been redesigned. We decided to order a 16 gauge, 12" x 22" large piece of aluminum sheet metal and bend it to the desired shape. Initially, two or three strips of the metal were going to be used, but after performing an FEA in Solidworks, we found the strips would have severe deformation and could possibly fail. For this reason and for reasons of comfort and stability, we decided to make a full 6.9" x 14" (after bending) back support. We will make this as soon as the ordered aluminum arrives.

    
Adam and Joel were able to make the motor functional. The motor's speed can be manipulated and work in forward and reverse states. They were also able to make the motor housing and shaft. The shaft is parallel to the motor and connects by a timing belt. Below is the motor attached to a potentiometer to control the speed.

Adam changes the speed of the motor
     
We are in the process of making the EMG sensor which will detect and determine when the motor is supposed to rotate. We have a Myoware sensor that will detect the electrical potential of the uterine muscle through electrodes placed on the surface of the woman's stomach and output a signal that correlates with the strength of the contraction and thus the strength at which the motor will cause the bands to contract. This should be finished by the end of next week.
The Myoware sensor; this will help us determine when the woman is contracting.