This week, we put the new motor configuration on the sheet metal. Other electronic mounts and housings are still being made. (Like the angle converter and such) We wanted to improve the comfort and ergonomics of the device by making the motors and associated electronics inside of the back support. This way, she does not have a large uneven weight on one side. Also, this means that we do not need as many housing components, so overall weight is reduced. We tried to make this further comfortable by putting the motors in the natural curvature of her back, which we will have to account for anyway.
Also, the new connection design was printed. One side printed out well, so that it was able to go onto the sheet metal with a very tight fit. The other side was printed poorly, so the holes for the seat belt were closed. That will need to be reprinted.
Lastly, we have begun the poster to explain our project to others. It still needs work (and pictures!), but that will be finished by next week hopefully.
Monday, April 10, 2017
Monday, April 3, 2017
Re-Evaluating our Options
This week during class, we sat down as a group and discussed the progress and status of the current prototype. The group agreed that our current prototype is not functioning the way it should be at this point. During last week's testing, the belt driving system broke and would not apply sufficient forces on the belt. This was determined to have been caused due to the weaker material strength of PLA being deformed by the set screws we were using. The reason that there is need of these set screws is due to the very small shaft diameter that is associated with the small motor. We met with our adviser and discussed possible alternatives of fixing the shaft to the timing belt pulley. Dr. Gordon offered some helpful information on a way of converting the shaft sizes to fit one another. However, after some research it was determined that there weren't any parts as small as our shaft. This discovery led the group along with the adviser to discuss possible redesigns of our prototype in order to have a functioning prototype by the end of the semester.
During class a few new ideas were brainstormed using the material and parts that we already have that could be salvaged. From these various ideas we came up with a method of positioning the belts and motors underneath the woman in a compartment attached to the back support piece. The configuration can be seen in the figure below.
Wyatt earlier this week was able to assemble the newest connection configuration. Once assembled, testing of the holding and shear forces could be tested. These two were tested to determine if the connection would hold while the system was operating and if the connection could be detached and reattached easily with proper alignment. Results showed expected ease of detachment but some redesign needs to be considered to assist shear resistance and alignment of the magnets.
During class a few new ideas were brainstormed using the material and parts that we already have that could be salvaged. From these various ideas we came up with a method of positioning the belts and motors underneath the woman in a compartment attached to the back support piece. The configuration can be seen in the figure below.
| In progress CAD model of the new configuration including mounted motors, with axles and partial belt fan on pronged side of sheet metal. |
Wyatt earlier this week was able to assemble the newest connection configuration. Once assembled, testing of the holding and shear forces could be tested. These two were tested to determine if the connection would hold while the system was operating and if the connection could be detached and reattached easily with proper alignment. Results showed expected ease of detachment but some redesign needs to be considered to assist shear resistance and alignment of the magnets.
Results from connection testing.
Monday, March 27, 2017
Testing the Functionality of our Device
| Sliding sleeve with polyethylene |
We have a plan in place to test the device's ability to move the baby down the birth canal. We will produce a mold and fill it with ballistics gel. We will then use our device on this mock woman and measure the displacement of the baby.
There have also been other improvements on our device. Adam has been fixing the motor mount and motor driver to make them more functional and efficient. He has finished the code and proven that the code does actually provide approximately the required voltage that it should. Wyatt has made a new connection that would take up less space and make putting the device on and off easier. All three will connect together and just snap on and off, instead of requiring rotation.
Monday, March 13, 2017
Broader Impacts & TACO 2
This week encompassed continued work on prototype #2 of the TACO and a written analysis of the broader impacts this device could have in a local and global context. Team EXIT had to research in what ways their device would impact these communities from a social, economic, safety, and environmental perspective and compose an essay stating their research and conclusions.
Ruthie has continued her work on the testing plan. She has rendered a mold within Solidworks that will give the team a general idea of how to construct the mother's abdomen out of the ballistics gel.
Joel has continued redesigning the offset converter and has come up with a visually simpler, yet anatomically complex solution. It involves several ribs that guide the band to the desired angle instead of an enclosed passageway. This reduces friction between the band and the housing by eliminating a large majority of the surface area.
Wyatt has begun disassembling the previous TACO electronics and has printed the modified electronics box and distal motor housing cover. Soldering of the motor drivers and Uno will begin shortly once the redesign of the motor housing is complete. Below is a picture of the nicely toleranced distal motor housing with the potentiometers and switches.
| Potentiometers and switches sit well within their designated spots. Note the flush surfaces between the switches and housing cover. Some additional superficial work is still underway. |
Ruthie has continued her work on the testing plan. She has rendered a mold within Solidworks that will give the team a general idea of how to construct the mother's abdomen out of the ballistics gel.
Adam has similarly continued his work in assembling the motor housing cover. He has also ordered and cut thicker stainless steel rods that will provide additional strength to the axles.
Monday, March 6, 2017
Midterm Milestone
This last week marked the midpoint of the semester. Therefore, it was time to update our client and adviser and our fellow classmates on the progress we have made thus far. Along with our presentation, we were able to display a somewhat functioning yet assembled prototype with most of our modules (the last added module will be the contraction sensor). However, there are still some redesigns that need to be made after the previous week's testing. Joel discovered some errors in his design that were disallowing smooth passage of the belt through his offset converter. The images below show what was wrong with his current design and his in-progress redesign:
An artifact of the loft caused a decrease in passage
length, kinking the band as it went through.
Current in-progress redesign within a portion of the motor housing.
Adam has begun work on improving the contact between the timing belts and the axles as well as reinforcing them so we will not have the same snapping problem as before. Also, in accordance with Adam and his work on the motor housing, Wyatt has made some minor changes to the electronics box and distal motor housing cover that will organize the electronics inside and add some aesthetic elements to the positioning of the switches and potentiometers.
Front view of the distal motor housing
cover. Note the three openings near the top for
the potentiometers and the switch openings beneath.
Minor design changes to the electronics box include hook attachments for wires, guides for the battery and arduino, and some spacing on the top of the interior walls for the screws that are on the gear motor brackets.
Lastly, Ruthie has begun some initial test planning so that we may verify our device's concept. This plan should be carried out once a completely functioning prototype is developed.
Monday, February 27, 2017
Snap! ...the sound of our almost functioning device...
This week, the team had several tasks on their mind: troubleshoot
the circuit (which last week had been soldered in the device), fix broken
spindles, get the entire system working, and prepare for the midterm design
review.
Early in the week,
Wyatt and Adam localized the issue of the circuit malfunction to
misunderstanding the pins of a mechanical switch used three times in the
device. After re-soldering the connections to the pins, the circuit read
the correct output signals, measured on an oscilloscope. A formal circuit diagram was drawn up. Now the only thing left
to do with the electronics is to tap leads from the electronics box to connect
to the EMG electrodes on the mother’s belly. These will be the one disposable part
of the design.
| Figure1. Soldered electronics box. |
| Figure2. Formal circuit diagram of T.A.C.O. electronics drawn in Multisim. |
| Figure3. Motor with new spindles functioning off the power supply without tension. |
Elated, we connected the entire system, and turned on the device.
With care, we began to turn the manual potentiometer for each motor and were
dismayed at the sound of snapping PLA! The timing belt was also still slipping
periodically. Some analysis shows this could have been predicted. The issues
were now isolated to the following: the set screws were too long, and stuck
out, causing the walls of the housing to obstruct their path as they spun with
the timing belt pulley; the timing belt pulley was still not concentric; and
the size of the PLA spindle end was unable to handle the stresses developed
when the motor was running with resistance. The system has been redesigned to
include a single metal axle for the spindle, which will extend from the band,
through the timing belt, into a bearing that will be connected to a mechanical
support for the timing belt system. The redesign will be drawn up in SolidWorks
next week.
In addition to all this, the converter had a failed print. This
showed us the cross section of the part, revealing unexpected geometry. Joel
worked with CBU’s resident 3D printing expert to redesign the converter to
account for this artifact of the previous design. Ruthie contacted Sierra-Medical about obtaining a cow uterus for testing, and logistics and detailed plans for this process are still being worked out. Wyatt redesigned the electronics box to better organize the electronics.
Preparation for the midterm design presentation was primarily remote,
because the team did not have coinciding schedule’s this week. The presentation
is taking place this afternoon, Monday, February 27th, at Bourns Laboratory at 2:45 p.m.
And last, but certainly not least, the team decided on a name for the device: The Assisted Childbirth Orthotic, or T.A.C.O.
And last, but certainly not least, the team decided on a name for the device: The Assisted Childbirth Orthotic, or T.A.C.O.
Monday, February 20, 2017
Summer Biomechanics, Bioengineering and Biotransport Conference
This week was the deadline to submit an abstract to the Summer Biomechanics, Bioengineering and Biotransport Conference. Therefore, we wrote about the reason why we made the device the way it is and the reason behind it. We briefly explained the design and included our budget. It is yet to be seen if we will be accepted to the conference.
| The first page of our abstract |
We had a brainstorming session about how we are going to test our device. So far, we thought that we might simulate the human body with Ballistics gel covered in pig skin. We may also get a Cow uterus (or whatever species is cheapest) with something to simulate the surrounding tissue. We would like to electronically simulate the uterus and vaginal area going through a birth with our device as well if that is possible. Below is a list of some of our ideas in order of what will give us the most information. We plan to do many of the tertiary level tests even though it doesn't prove our device's ability to get the baby out because they still give us important information
- Primary
- Ballistics gel
- Pig skin
- Knox gelatin mix
- Grant Imahara
- Cow
- Uterus
- Vaginal wall
- Supporting ligaments
- Pig skin
- Pelvic structure
- Talk to Gordon about Abacus
- Secondary
- Band contractile ability
- Force transducers on sliders
- Pressure sensors on back (low priority)
- Box
- Tertiary
- IR Camera
- Hot spots
- Full charge/discharge
- Cycles/frequency
- Ability of woman to move
- Test electronics
- Emergency take off
- Kill switches
- Reverse functionality
We improved our code by adding more situations. For example, we added in a cyclic setting that would run the motor on and off with no input. This would only be used for demonstration or testing purposes. We also added safety measures like what would happen if the sensors are not attached.
![]() |
| Our motor driver and Arduino connections |
The motor housing was finished. Some parts did not fit at first because of tolerancing problems and improper placement of screws, but we fixed it with power tools. The motors are functional.
| Add caption |
We 3D printed a part to hold the connection to the back. The connection will loop through this part. This has a 180 degree hinge to allow for flexibility and comfort for the woman.
Below is a picture of the current prototype (90% completed).
| T.A.C.O. (The Assisted Childbirth Orthotic) first prototype. |
Monday, February 13, 2017
Building a Prototype
We have been very busy making each of the components of the prototype. Wyatt has been trying to get the parts of the connection to fit after printing high-precision parts. He was able to reprint it and get the connection fully functional! The two halves each attach very well to the seat belt. When you put them together, the magnets hold them together with a lot of force, but when you turn the dial then they repel each other to disconnect easily.
I tested out the sensor on Wyatt's arm. I was able to obtain an output that corresponds to the level of contraction his muscles were under. I found that when his arm is at rest we receive an output in the 70's and when he contracts his muscles then we receive an output in the order of the hundreds. We were able to integrate the sensor with the motor.
Meanwhile, we finished designing the motor housing. This housing has many slots to place the seat belt in to fit different sizes of women. The parts are currently being printed. We should be done assembling them in the next couple of days.
Demonstration of connection attachment and release along with a short test of the holding force of the assembly.
I tested out the sensor on Wyatt's arm. I was able to obtain an output that corresponds to the level of contraction his muscles were under. I found that when his arm is at rest we receive an output in the 70's and when he contracts his muscles then we receive an output in the order of the hundreds. We were able to integrate the sensor with the motor.
| Ruthie and Wyatt test out the sensor |
The motor housing in solidworks
|
| The motor housing with the cover removed to see inside |
We finished redesigning and building the back support. We went into the shop so that we could cut, bend, and fillet the 16 gauge aluminum that we ordered. We plan on screwing it into the motor housing that will be on the left side of it. We will also screw it into a 3D printed part that has holes for the connection to fit through. We thought of putting those hole in the metal, but an FEA showed us that it might break due to very small strips that would have to hold all of the force from the motor. If we 3D print it, we can make it as thick as we want for stability. That part was designed and will be printed soon.
We made the metal back brace in the machine shop.
![]() |
| The metal part of the back support. The left side is where the motor housing will attach. |
We previously did research on the shape of the woman's back, so after the metal part was done we cut and placed the foam in a position that would be comfortable to the woman. This foam compresses significantly, so we added many layers. We are looking into a spray glue that should hold them in place without corroding the foam or being uncomfortable.
We are almost done with the prototype! We just need to put everything together and add any final details. I am really excited to see the final product!
![]() |
The Back support with foam
|
Sunday, February 5, 2017
Busy Builders
Team EXIT has been busy redesigning and building the first prototype. Wyatt tested the functionality of various revisions of the connections to determine the most optimal tooth arrangement. Unfortunately, the force transducer was broken causing him to use two other force transducers of smaller magnitudes. This still allowed a relatively good estimate of which fixtures would withhold our required strength when pulled from the same point. The results were largely dependent on the quality and precision of the print.
| The connection is clamped while the force sensors are pulled while attached to the seat belt |
| The FEA analysis |
Adam and Joel were able to make the motor functional. The motor's speed can be manipulated and work in forward and reverse states. They were also able to make the motor housing and shaft. The shaft is parallel to the motor and connects by a timing belt. Below is the motor attached to a potentiometer to control the speed.
Adam changes the speed of the motor
|
We are in the process of making the EMG sensor which will detect and determine when the motor is supposed to rotate. We have a Myoware sensor that will detect the electrical potential of the uterine muscle through electrodes placed on the surface of the woman's stomach and output a signal that correlates with the strength of the contraction and thus the strength at which the motor will cause the bands to contract. This should be finished by the end of next week. ![]() |
| The Myoware sensor; this will help us determine when the woman is contracting. |
Monday, January 30, 2017
Crunch Time
As per the deadlines given to us at the start of the semester, Team EXIT has been diligently working this week to maximize the time we have in the semester for testing and verification of our prototype. Earlier in the week, Adam and Joel had a chance to present to our tech adviser their concepts for the motor spatial design. After some considerations were brought to our attention, they set about redesigning the motor arrangement to be more accommodating to the mother yet equally as effective. Below is the assembly of their work to date.
Left, right and isometric views of the motor spatial design.
Meanwhile, Wyatt has been busy designing an alternative method to attaching our connection assemblies to the band. This is an alternative concept to our original idea of sewing a pocket on the band to hold the assemblies. This new method would allow for detachment and attachment of the connectors at a selected location. The band would be held within two pieces that are snapped together using a plastic snap fit. These pieces would also have small "teeth" to prevent slipping of the belt from between the two pieces. Below are some conceptual designs that will later be tested to determine the best tooth design for least amount of slippage and highest holding strength.
Bottom and top fixtures that are to be tested and will later become the base for the connectors to attach to the band.
Continuing research and design has been put into developing a sensor that would detect the contractions and allow our bands to assist the mother when appropriate. These sensors would be fitted into the bands. Ruthie and Wyatt will continue work on this and have something functional close to the deadline.
Still much more exciting work to be done!
Sunday, January 22, 2017
Back In Action
During the following week, Adam and Joel met to further develop the software and hardware we would need to have a motor capable of pulsing with modulation or PWM. Originally the plan was to use an Arduino UNO with some simple code to create the modulation. This then evolved into a more complex circuit utilizing a single transistor and potentiometer. Using the circuit allowed us to adjust the speed of the motor in a single direction. However, what was needed was the ability to modulate forwards and backwards. That meant using four transistors set up as can be seen below.
![]() |
| Figure 2: Working circuit |
![]() |
| Figure 1: Circuit diagram |
![]() |
| Figure 3: Adam assembling the circuit |
| Figure 4: Order of motor driver |
Further brainstorming was necessary to resolve this issue and the drawings from this session can be seen below. The winning design modification is difficult to explain and there are no final CAD files currently. However, this new design will allow all three motors to fit in a much smaller space as well as allow the straps to be adjustable to conform to the dynamic shape of a mother's abdomen. The system will consist of a gear shaped guide rail with three belt guides that convert the direction the belt is facing while also minimizing the torsional stresses felt by the motor. This new "gearbox" will also be able to hold all electronics and connect to the rigid back support.