Monday, February 20, 2017

Summer Biomechanics, Bioengineering and Biotransport Conference


      This week was the deadline to submit an abstract to the Summer Biomechanics, Bioengineering and Biotransport Conference. Therefore, we wrote about the reason why we made the device the way it is and the reason behind it. We briefly explained the design and included our budget. It is yet to be seen if we will be accepted to the conference.

The first page of our abstract

      We had a brainstorming session about how we are going to test our device. So far, we thought that we might simulate the human body with Ballistics gel covered in pig skin. We may also get a Cow uterus (or whatever species is cheapest) with something to simulate the surrounding tissue. We would like to electronically simulate the uterus and vaginal area going through a birth with our device as well if that is possible. Below is a list of some of our ideas in order of what will give us the most information. We plan to do many of the tertiary level tests even though it doesn't prove our device's ability to get the baby out because they still give us important information


  1. Primary
    1. Ballistics gel
      1. Pig skin
      2. Knox gelatin mix
    2. Grant Imahara
    3. Cow
      1. Uterus
      2. Vaginal wall
      3. Supporting ligaments
      4. Pig skin
      5. Pelvic structure
    4. Talk to Gordon about Abacus
  2. Secondary
    1. Band contractile ability
      1. Force transducers on sliders
    2. Pressure sensors on back (low priority)
      1. Box
  3. Tertiary
    1. IR Camera
      1. Hot spots
      2. Full charge/discharge
      3. Cycles/frequency
    2. Ability of woman to move
    3. Test electronics
      1. Emergency take off
      2. Kill switches
      3. Reverse functionality

      We improved our code by adding more situations. For example, we added in a cyclic setting that would run the motor on and off with no input. This would only be used for demonstration or testing purposes. We also added safety measures like what would happen if the sensors are not attached.
Our motor driver and Arduino connections

      The motor housing was finished. Some parts did not fit at first because of tolerancing problems and improper placement of screws, but we fixed it with power tools. The motors are functional.




Add caption


We 3D printed a part to hold the connection to the back. The connection will loop through this part. This has a 180 degree hinge to allow for flexibility and comfort for the woman.


Below is a picture of the current prototype (90% completed).

T.A.C.O. (The Assisted Childbirth Orthotic) first prototype.


No comments: