    This week, team EXIT member, Adam Goodwin, finalized the calculations needed to determine specific parameters to guide our group in finding a cheap motor that would suit our needs. From the calculations it was determined that the motor should be able to apply a minimum of 12 in*lbs of torque. Using a motor that meets this parameter will hopefully be able to apply a necessary force in the belt webbing of approximately 25 lbs. The goal is to transfer this force equally around the abdomen to assist the mother during her contractions. 
Figure 1: Calculation Results
Regarding motor selection, Electrical Construction and Maintenance (ECM) shared helpful tips. One of the most relevant was tip 7, that the motor should normally operate at 75 to 95% of the mx torque. Also, most motors have a safety factor of around 1.15 for power rating, so for momentary application, it could likely deliver more than its specified horse power. However, given pro tips from senior Electrical and Computer Engineering major, Cameron Schaefer, we will try to keep our max torque used less than the specified max torque to avoid breaking our motor.
    Using this information, team EXIT collaborated together to create a list of possible motors from various suppliers that would meet the above specifications. From this list we were able to confidently choose a motor to use on our device. The selected motor is from a company called Pololu which specializes in the distribution of various electronic parts and equipment including motors. Along with the motor, our group decided that it would be best to power the motor with a rechargeable battery. Below is a list of the parts that we ordered this week. 
Figure 2: Motor Selection Matrix
    Aside from the motor being ordered along with its accompanying parts; we received the parts that were ordered last week which included the poly magnet, the belt webbing, and the padded belt slider. Since we had the magnets to work with, Wyatt Dean was able to 3D print the connector fittings and perform initial fitting tests, as well as, design iterations to fix some tolerance issues. A preliminary shakedown was also performed on the belt and slider to see if there was a sufficiently low enough coefficient of friction to allow the parts to slide freely. This coming week, we plan to use a tensometer to test the coefficients of friction. Monday, the plan is to perform tensile tests on small segments of our belt webbing to see how much force it can withstand in tension.
    Moving forward, if this week's tests prove to be successful, we hope to have one belt and motor functioning by the end of the week per our client's request. 